Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 13(1): 17491, 2023 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-37840093

RESUMO

The objectives of this study were to evaluate the stress distribution and risk of fracture of a non-vital immature maxillary central incisor subjected to various clinical procedures using finite element analysis (FEA). A three-dimensional model of an immature central incisor was developed, from which six main models were designed: untreated immature tooth (C), standard apical plug (AP), resin composite (RC), glass-fibre post (GFP), regeneration procedure (RET), and regeneration with induced root maturation (RRM). Mineral trioxide aggregate (MTA) or Biodentine® were used as an apical or coronal plug. All models simulated masticatory forces in a quasi-static approach with an oblique force of 240 Newton at a 120° to the longitudinal tooth axis. The maximum principal stress, maximum shear stress, risk of fracture, and the strengthening percentage were evaluated. The mean maximum principal stress values were highest in model C [90.3 MPa (SD = 4.4)] and lowest in the GFP models treated with either MTA and Biodentine®; 64.1 (SD = 1.7) and 64.0 (SD = 1.6) MPa, respectively. Regarding the shear stress values, the dentine tooth structure in model C [14.4 MPa (SD = 0.8)] and GFP models [15.4 MPa (SD = 1.1)] reported significantly higher maximum shear stress values compared to other tested models (p < 0.001), while no significant differences were reported between the other models (p > 0.05). No significant differences between MTA and Biodentine® regarding maximum principal stress and maximum shear stress values for each tested model (p > 0.05). A maximum strain value of 4.07E-03 and maximum displacement magnitude of 0.128 mm was recorded in model C. In terms of strengthening percentage, the GFP models were associated with the highest increase (22%). The use of a GFP improved the biomechanical performance and resulted in a lower risk of fracture of a non-vital immature maxillary central incisor in a FEA model.


Assuntos
Incisivo , Silicatos , Análise de Elementos Finitos , Compostos de Cálcio
2.
Odontology ; 111(4): 910-915, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36917401

RESUMO

To compare the amount of extruded debris caused by different motions using a single-file system. Fifty mandibular first molar teeth were randomized into 5 groups (n = 10) according to the motion tested: Optimize Torque Reverse (OTR), TF Adaptive Motion (TFA), continuous rotation (CR), reciprocation motion (+ 150°, -30°) (REC), and Jeni motion (Jeni). One Curve single file 25/06 (Micro-Mega, Besançon, France) was used in all experimental groups. The root canals were irrigated with 2.5% NaOCl, and the extruded debris were collected at pre-weighted glass vials. The glass vials were kept inside an incubator for one week at 70 °C to dry out the irrigating solution. The extruded debris was quantified by subtracting the pre-instrumentation from the post-instrumentation weight of the glass vials. The time required for each instrumentation procedure was digitally recorded. All data were analyzed statistically with one way ANOVA and post hoc Tukey test (P < 0.05). All the motions extruded apically debris with Jeni mode caused significantly less debris extrusion than TFA, REC, and CR (P < 0.05) while no significant difference emerged with OTR. Preparation time was not significantly different in all groups. Within the limits of the present study, all the kinematics produced apically debris extrusion, with Jeni reporting a similar amount of debris compared with OTR and significantly less than TFA, REC, and CR. Preparation time was similar among the tested kinematics.


Assuntos
Preparo de Canal Radicular , Ápice Dentário , Fenômenos Biomecânicos , Cavidade Pulpar , Dente Molar
3.
Sci Rep ; 12(1): 17137, 2022 10 13.
Artigo em Inglês | MEDLINE | ID: mdl-36229628

RESUMO

The prevalence and anatomical features of C-Shaped Mandibular Second Molars (MSMs) are rarely studied in Jordanian sub-population. This study then took a part to evaluate the prevalence of C-shaped in MSMs using cone-beam computed tomography (CBCT) in the Jordanian sub-population. It used a cross-sectional design and three thousand scans collected over eight years between 2011 and 2019. The data were then reviewed for whether they were fully formed of MSMs. A total of 2037 cases that had 2845 MSMs were evaluated to identify C-shaped canals at coronal, middle, and apical sites. An oblique slicing module perpendicular to the long axis of MSMs was used to evaluate the teeth. The type and frequency of C-shaped canals, as well as the correlations between sex and side (right/left) and between sex and groove direction (buccal/lingual) were measured using the chi-square test on SPSS software at the significance level of 95%. A total of 342 teeth of 243 patients were C-shaped molars, which comprised 12% of the patient's teeth and 99 of them as a bilateral C-shaped canal with mean age of 40 years and sex ratio of 2:1 between female and male. With the limitations of this study, the lingual groove and type 3 were the most common properties of MSM. Besides, the Jordanian population mostly had C-shaped canals.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Mandíbula , Dente Molar , Adulto , Tomografia Computadorizada de Feixe Cônico/métodos , Estudos Transversais , Feminino , Humanos , Jordânia/epidemiologia , Masculino , Mandíbula/diagnóstico por imagem , Dente Molar/anatomia & histologia , Dente Molar/diagnóstico por imagem , Prevalência
4.
Aust Endod J ; 48(2): 245-250, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34125465

RESUMO

The apically extruded debris caused by TruNatomy System (TRN), RACE EVO system (RE) and VDW Rotate (VR) systems in mandibular anterior teeth with ribbon-shaped root canals were compared. The root canals (n = 20 in each group) were irrigated with NaOCl 2.5%, and the extruded debris was collected at pre-weighted Eppendorf tubes. The amount of apically extruded debris (mg) and the treatment time (s) were recorded. Tukey pairwise comparisons were performed to compare groups with a 95% confidence level. VR had significantly less debris extrusion values and treatment time than RE and TRN (P < 0.05). Although no difference was observed between RE and TRN in terms of apically extruded debris (P > 0.05), a significant difference in favour of RE was observed in terms of treatment time (P < 0.05). All the instruments extruded debris at varying weights.


Assuntos
Preparo de Canal Radicular , Ápice Dentário
5.
J Endod ; 47(6): 976-981, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33737004

RESUMO

INTRODUCTION: This laboratory-based study aimed to investigate the quantitative amount of apically extruded debris from severely curved root canals and the preparation time for the novel rotary system TruNatomy (TN; Dentsply Sirona, Charlotte, NC) compared with Reciproc Blue (RCB; VDW Dental, Munich, Germany), HyFlex (HyFlex Controlled Memory [HCM; Coltene/Whaledent, Altstatten, Switzerland] and HyFlex EDM [HEDM, Coltene/Whaledent]), and ProTaper Next (PTN; Dentsply Maillefer, Ballaigues, Switzerland) rotary systems. METHODS: One hundred mandibular molar human teeth with severe curvature of the mesiobuccal canal (25°-45°) were included in the present study. The specimens were randomly distributed into 5 balanced groups (n = 20): TN, RCB, HCM, PTN, and HEDM. The amount of extruded debris for each group during instrumentation at body temperature was collected in an Eppendorf tube. After desiccation, the mean debris weights for each group were calculated. The total preparation time for each group was also recorded. Data were statistically analyzed using the Kruskal-Wallis test at a significance level of P < .05. RESULTS: The HCM and HEDM groups extruded a significantly higher amount of debris than the other tested groups (P < .001). TN extruded the least amount of debris, but it was not significantly different compared with the RCB and PTN groups (P > .05). In terms of preparation time, the TN group did not show any significant difference compared with the other groups. CONCLUSIONS: All instrumentation systems extruded debris. TN was among the groups that produced the lowest amount of apically extruded debris that is clinically acceptable. The amount of apically extruded debris using the TN system was equal to 2 popular systems and statistically significantly less than 2 other popular systems studied.


Assuntos
Níquel , Preparo de Canal Radicular , Cavidade Pulpar , Desenho de Equipamento , Alemanha , Humanos , Titânio , Ápice Dentário
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...